Derived from the Technology Development Mountain of NASA's Space Program (PARSEC®) PARSEC® Space metal foil has excellent insulation, moisture-proof, and thermal insulation effects, and is widely used in national sports venues, national grain depots, commercial buildings, residential, agricultural, and industrial buildings.
(PARSEC®)PARSEC® Space metal foil has excellent insulation, moisture-proof, and thermal insulation effects, and is widely used in national sports venues, national grain depots, commercial buildings, residential, agricultural, and industrial buildings. PARSEC® Space metal foil can highly reflect and block radiation heat, while possessing extremely strong tension and will not deform, saving construction costs and manpower. It is a high-quality energy-saving product with the latest technology. PARSEC® Space metal foil system continues to expand to other applications and actively develops its characteristics.

| Testing items | Testing result | Testing standards |
| Near infrared reflectance | ± 95% (double sided) | (ASTM C1371-98) |
| Longitudinal tensile strength | 37Mpa | (JC/T 2290-2014) |
| Transverse tensile strength | 38Mpa | (JC/T 2290-2014) |
| Nail rod tear strength - longitudinal | 139N | (JC/T 2290-2014) |
| Nail rod tear strength - transverse | 115N | (JC/T 2290-2014) |
| Low temperature bending | -20℃, No cracks | (JC/T 2290-2014) |
| Impermeability | 0.3Mpa, no leakage for 30 minutes | (JC/T 2290-2014) |
| Hot air aging - longitudinal tension (80℃/168h) |
38Mpa | (JC/T 2290-2014) |
| Hot air aging - lateral tension (80℃/168h) |
40Mpa | (JC/T 2290-2014) |
| Hot air aging - elongation rate at maximum longitudinal force (80℃/168h) |
9% | (JC/T 2290-2014) |
| Hot air aging - elongation rate at maximum lateral force (80℃/168h) |
10% | (JC/T 2290-2014) |
| thermal conductivity | 0.035W/(m, k) (Containing 50mm thick rock wool with a unit weight of 120K) |
(GB/T 10295-2008) |
| Surface flame resistance | 1 level | (BS 476 Part 7) |
| Flame spread | 0 level | (BS 476 Part 6) |
| Water vapor permeability | 0.019 g/square meter/day | (ASTM E96 ProcedureA) |
| Salt spray test | no effect | (MTL-STD-810 Method 507) |
| Moisture test | no effect | (MTL-STD-810 Method 509) |
| Acid resistance | unchanged | 5% HCL impregnated surface for 48 hours 2% HCL impregnation surface for 168 hours |
| Weight and dimensions | Size: 1.25mX96mx0.15mm Roll weight: ± 22kg |